DB500 Controller
Solar Hot Water- - > DB500 Drainback

DB500 Drain Back Controller
DB500_ Controller_ (Trimline) 1.jpgDB500 _Controller_ (Trimline) 2.jpg
Trimline Design Centre Inc. presents the DB500 Drain Back Controller.-  The DB500 is a versatile controller designed to meet the task of controlling your solar hot water heating system.-  The DB500 accepts up to three sensor inputs and provides two AC power outputs.-  An alarm output is included to provide remote error indication.-  Modern microprocessor technology provides accurate control and data logging capabilities.-  A variety of sensors are available to monitor the operation of your system.
Features

Microprocessor control:-  Modern control technology
Programmable internal clock
Includes hard reset switch
Data logging capabilities:Time co-ordinated data logging
User friendly data retrieval software
DB9 RS232 serial communications connection
LED indicators:Power indicator
Output indicator (x2)
Alarm indicator
Mode indicator:-  Normal operation- - 
Data logging operation
- - - 
Data download operation
Four sensor probe inputs:Analog to digital inputs
Various applicable temperature and sensor options
Two high temperature thermocouple options
Three isolated outputs: Each output includes a LED indicator
Each output includes a momentary action test switch
Rated at 5 amps each:- - 
Output 1: Triac switched 120 VAC linepower

Output 2 :Triac switched 120 VAC- 
linepower

Alarm:- -  Set of normally open relay contacts
All metal enclosure:Hinged front access doorMultiple knockouts for ease of wiring
Optional display (in progress)
Specifications
Input Power- - - - - - - - - - - - - - - - - -  120 VAC
Output Rating- - - - - - - - - - - - - - -  5A at 120 VAC

Data Log Sample

Log Time T1 T2 Pump Log # Month DateCELSIUS CELSIUS 0=Off/1=On 1 5 11
8:30:00 27 29 0 2
8:40:00 28 29 0 3
8:50:00 31 29 0 4
9:00:00 37 29 0 5
9:10:00 40 29 0 6
9:20:00 36 29 1 7
9:30:00 36 29 0 8
9:40:00 36 29 0 9
9:50:00 41 29 1 10
10:00:00 33 29 0 11
10:10:00 36 30 1 12
10:20:00 42 29 1 13
10:30:00 40 30 1 14
10:40:00 37 29 0 15
10:50:00 37 30 1 16
11:00:00 41 30 1 17
11:10:00 35 30 0 18
11:20:00 38 30 1 19
11:30:00 45 30 1 20
11:40:00 38 30 0 21
11:50:00 37 30 1 22
12:00:00 37 31 1 23
12:10:00 40 30 1 24
2:20:00 39 30 1 25
12:30:00 40 31 1 26
12:40:00 35 31 0 27
12:50:00 38 31 1 28
13:00:00 38 31 0 29
T1: Apricus AP-22 header
temperature

DB500_ Controller_(Trimline) 3.jpg
13:00:00 38 31 0 29
13:10:00 38 31 1 30
13:20:00 39 31 1 31
13:30:00 45 31 1 32
13:40:00 43 32 1 33
13:50:00 43 32 1 34
14:00:00 39 33 0 35
14:10:00 40 33 1 36
14:20:00 40 33 0 37
14:30:00 41 34 1 38
14:40:00 46 34 1 39
14:50:00 46 34 1 40
15:00:00 47 35 1 41
15:10:00 43 35 0 42
15:20:00 41 35 1 43
15:30:00 47 35 1 44
15:40:00 42 35 0 45
15:50:00 42 36 0 46
16:00:00 40 36 0 47
16:10:00 47 35 1 48
16:20:00 40 36 0 49
16:30:00 44 36 0 50
16:40:00 46 36 0 51
16:50:00 47 36 0 52
17:00:00 40 36 0 53
17:10:00 43 37 0 54
- - - - - - - - - - - - - - - - - - - - 
T2: Tank Temperature- 
DB500 _Controller_(Trimline) 4.jpg