Mark PV Controller
Solar Electric-  > Mark PV Controller- 



DESCRIPTION

The Specialty Concepts, Inc. MARK 15 is a cost effective, flush mount, battery charge controller with digital system monitoring. The MARK 15 is available for 12 or-  24- volt systems with charging current up to 15 amps, and provides efficient charging while protecting the batteries from damage due to overcharging. This controller is designed for use in mobile or station ary photovoltaic energy systems, with complete system monitoring of battery voltage, solar charging current, and charge set-point calibration. Charge-mode status lights, battery condition LED bar-graph, a blocking diode, battery fuse and array fuse are standard.
Mark_PV_Controller.jpg

FEATURES

CHARGE REGULATION
15 amp charge current, 12 or 24 volt Easily handles over-currents
Switching shunt, LFCS pulse charg
ing method
Field adjustable set-points

DESIGN FEATURES
100% solid-state
Designed for rugged mobile use
Over-current protection - battery fuse, array fuse
Reverse leakage protection - blocking
diode
Reverse polarity protection
Lightning protection
Input noise suppression
Low power consumption
12 awg terminal block
OPERATION

SWITCHING SHUNT REGULATION -
The
MARK 15 will allow maximum array current to flow into the battery through a blocking diode, lighting the "SOLAR CHARGING" light (LED), until the battery voltage reaches the charge termination set-point. At this point, a shunt transistor will turn on, shunting the solar array, turning off the "SOLARCHARGING" LED, lighting the "BATTERY CHARGED" light and halting any further battery charging.
OPTIONS DESCRIPTION

A -Temperature Compensation:
Temperature compensation is generally recommended for sealed batteries or where batteries are expected to experience temperature variations of more than +10from 25-°C during periods of charging. A small temperature sensor on a 10 foot lead monitors actual battery temperature and adjusts the charging thresholds according to battery temperature. The rate of compensation is -5mv/-°C per battery cellfrom 25-°C.
MONITORING
Digital monitoring of:
- a) System battery-  voltage
b) Solar charge current
c) Charge set-point calibration
"SOLAR CHARGING" light
"BATTERY CHARGED" light
LED bar-graph BATTERY CONDITION indicator
BAR or DOT display
Power saver display mode
When the battery voltage drops to the charge resumption set-point, the shunt transistor will turn off and charging will resume. The result is that when battery capacity is low, charging will be continuous. As the battery charges up, current will pass into the battery for shorter and shorter periods, until at full charge, it will pulse current into the battery to achieve and maintain full charge.
E - Low Voltage Disconnect (LVD) / Generator Start:
The MARK 15 can be provided with an auxiliary relay. This relay can be used to protect the battery from low-voltage damage by disconnecting loads or by signaling a standby generator to start or stop battery charging. The relay is rated for 10 amps. This option provides the common, the normally open and the normally closed voltage-free contacts of the relay.


MOUNTING
Flush mount
Knock-out box available for wall mounting (4x7 BOX accessory)
ACCESSORIES

4X7 BOX
- Knock-out box used for wall mounting.


Weight: 0.49 lbs


MARK 15

PLEASE CALL FOR SHIPPING-  QUOTE-  IF YOU ARE ORDERING OUTSIDE CANADA !!!



Mark-22 12V- $184.29


We respect your email privacy! Trimline Design Centre promises never to share, sell or trade your- personal contact information with other parties without your authorization or approval first. You have our word.

Download Brochure






MARK 15 äSpecialty Concepts, Inc.